Ryobi A25RT02 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
ELECTRICAL
SPEED AND WIRING
The no-load speed of this product depends on the router
you are using. This speed is not constant and decreases
under a load or with lower voltage. For voltage, the wiring
in a shop is as important as the motor’s horsepower rating.
A line intended only for lights cannot properly carry a power
product motor. Wire that is heavy enough for a short dis-
tance will be too light for a greater distance. A line that can
support one power product may not be able to support two
or three products.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding pro-
vides a path of least resistance for electric current to reduce
the risk of electric shock. This product is equipped with an
electric cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Improper connection of the equipment-grounding conduc-
tor can result in a risk of electric shock. The conductor with
insulation having an outer surface that is green with or without
yellow stripes is the equipment-grounding conductor. If repair
or replacement of the electric cord or plug is necessary, do
not connect the equipment-grounding conductor to a live
terminal.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if
in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This product is intended for use on a circuit that has an outlet
like the one shown in figure 1. It also has a grounding pin
like the one shown.
Fig. 1
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong grounding
plugs and 3-pole receptacles that accept the product’s plug.
When using a power product at a considerable distance from
the power source, use an extension cord heavy enough to
carry the current that the product will draw. An undersized
extension cord will cause a drop in line voltage, resulting in
a loss of power and causing the motor to overheat. Use the
chart provided below to determine the minimum wire size
required in an extension cord. Only round jacketed cords
listed by Underwriter’s Laboratories (UL) should be used.
**Ampere rating (on product data plate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25' 16 16 16 16 14 14
50
' 16 16 16 14 14 12
100
' 16 16 14 12 10
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the product outdoors, use an extension
cord that is designed for outside use. This is indicated by the
letters “WA” on the cord’s jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
products or other obstructions while you are working with
a power product. Failure to do so can result in serious
personal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use product with a damaged
cord since touching the damaged area could cause elec-
trical shock resulting in serious injury.
ELECTRICAL CONNECTION
This product should be connected to a power supply that is
120 volts, 60 Hz, AC only (normal household current). Do
not operate this product on direct current (DC). A substantial
voltage drop will cause a loss of power and the motor will
overheat. If the router table does not operate when plugged
into an outlet, double check the power supply.
GROUNDING
PIN
120 V GROUNDED OUTLET
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 19 20

Comments to this Manuals

No comments