CHAPTER 1 SCREEN OPERATIONS
5. Diagnosis Screens
I – 172
5.3.2 Carrying out modal output
Modal type forced output of PLC interface signals is carried out. Once set, this data is held until canceled,
the power is turned ON/OFF, or other data is overwritten. There are four sets of devices that modally
output. If this number is exceeded, the previously existing data is overwritten.
(1) Menus used in modal output
Menu Details Type Reference
Modal
all clr
Modal output of all devices in the modal output area is
canceled in a batch.
The canceled data is erased from this area.
C
(3) Canceling
modal output in a
batch
Modal
sgl clr
Modal output of the device at the position of the cursor
in the modal output area is independently canceled.
The canceled data is erased from this area.
C
(4) Independently
canceling modal
output
(2) Modally outputting data "1" to device "X0048"
1)
The modal output mode is entered, and the cursor
appears at the modal output area.
2)
3)
Modal output is executed, and the cursor disappears.
The data that was in the cursor position is overwritten
by the input data, and is invalidated.
The modal output mode is canceled by pressing the
key.
(Note) The data of the modally output device is displayed in order in the selected area.
This modal output is held until the output is canceled or the power is turned OFF.
Press the menu key
Modal output
.
Using the
and
keys,
move the cursor to the setting
position.
Set the device and data, and
press the
INPUT
key.
X0048/1
INPUT